Quality Changes in Fundus Images of Pseudophakic Eyes

M. S. Millán, A.G. Marrugo, F. Alba-Bueno


Download Paper

Base Information

Volume

V51 - N4 / 2018 Ordinario

Reference

50015:1-8

DOI

http://doi.org/10.7149/OPA.51.4.50015

Language

English

Keywords

Digital image analysis; image quality, eye fundus image; intraocular lens, pseudophakia, non-mydriatic retinal camera

Abstract

We consider the changes produced in the quality of eye fundus images of patients before and after cataract surgery with intraocular lens implantation and propose a measure to quantitatively assess those changes. Several factors concerning the optical system of the eye, the ocular media, and the specific characteristics of the implanted intraocular lens, may influence the quality of the digital image acquired with a non-mydriatic retinal camera. We illustrate our study with several cases taken from the clinical practice. A pair of pre- and post-operative eye fundus images represents each case. To measure image quality, we carry out a calculation of image anisotropy on each image. The results show that after surgery with intraocular lens implant, a fundus image is usually much brighter, sharp and higher quality. However, this rule of thumb can be altered by several conditions. For example, the multifocal design of the intraocular implant after a clear lens extraction. The anisotropy-based measure has revealed to be a suitable tool to quantitatively assess quality changes between pre-and post-operative fundus images.

References

0

M. D. Abramoff, M. Garvin, and M. Sonka, "Retinal Imaging and Image Analysis," Biomedical Engineering, IEEE Reviews in, 3, pp. 169-208, (2010).

1

L. Abdel-Hamid, A. El-Rafei, S. El-Ramly, G. Michelson, and J. Hornegger, "Retinal image quality assessment based on image clarity and content," J. Biomed. Opt., 21(9), p. 096007, (2016).

2

A. D. Fleming, S. Philip, K. A. Goatman, J. A. Olson, and P. F. Sharp, "Automated assessment of diabetic retinal image quality based on clarity and field definition," Invest Ophth Vis Sci, 47(3), pp. 1120-1125, (2006).

3

A. G. Marrugo, M. S. Millan, G. Cristóbal, S. Gabarda, and H. C. Abril, "No-reference quality metrics for eye fundus imaging," presented at the CAIP'11: Proceedings of the 14th international conference on Computer analysis of images and patterns, 6854 pp. 486-493 (2011).

4

L. Giancardo, M. D. Abramoff, E. Chaum, T. Karnowski, F. Meriaudeau, and K. Tobin, "Elliptical local vessel density: A fast and robust quality metric for retinal images.," Annual Int Conf of the IEEE Engineering in Medicine and Biology Society, 1(4), pp. 3534-1179, (2008).

5

J. L. Alió, P. Schimchak, R. Montés-Micó, and A. Galal, "Retinal image quality after microincision intraocular lens implantation," Journal of Cataract & Refractive Surgery, 31(8), pp. 1557-1560, (2005).

6

D. Siedlecki, M. Zajac, and J. Nowak, "Retinal images in a model of a pseudophakic eye with classic and hybrid intraocular lenses," Journal of Modern Optics, 55(4) pp. 653-669, (2008).

7

H. Guo, A. V. Goncharov, and C. Dainty, "Comparison of retinal image quality with spherical and customized aspheric intraocular lenses," Biomedical Optics Express, 3(4), pp. 681-691, (2012).

8

H. Zhao and M. A. Mainster, "Ghost Images And Retinal Image Quality In Pseudophakic Eyes," Invest Ophth Vis Sci, 52(14), pp. 6184-6184, (2011).

9

A. G. Marrugo, M. S. Millan, G. Cristóbal, S. Gabarda, and H. C. Abril, "Anisotropy-based robust focus measure for non-mydriatic retinal imaging," J. Biomed. Opt., 17(7), p. 076021, (2012).

10

M. Subbarao, T. Choi, and A. Nikzad, "Focusing techniques," Optical Engineering, 32(11), pp. 2824- 2836, (1993).

11

P. Bedggood, M. Daaboul, R. Ashman, G. Smith, and A. Metha, "Characteristics of the human isoplanatic patch and implications for adaptive optics retinal imaging," J. Biomed. Opt., 13(2), p. 024008, (2008).

12

G. Wallace, "The JPEG still picture compression standard," IEEE Trans on Consumer Electronics, 38(1), pp. xviii-xxxiv, (1992).

13

J. Ramirez, A. Garcia, P. Fernandez, L. Parrilla, and A. Lloris, "A new architecture to compute the discrete cosine transform using the quadratic residue number system," IEEE International Symposium on Circuits and Systems, 5, pp. 321-324, (2000).

14

C. Stewart, Chia-Ling Tsai, and B. Roysam, "The dual-bootstrap iterative closest point algorithm with application to retinal image registration," Medical Imaging, IEEE Transactions on, 22(11), pp. 1379- 1394, (2003).

15

L. Fernández-Vega, J. F. Alfonso, and T. Villacampa, "Clear lens extraction for the correction of high myopia," Ophthalmology, 110(12), pp. 2349-2354, (2003).

16

M. Niemeijer, J. Staal, B. van Ginneken, M. Loog, and M. D. Abramoff, "Comparative study of retinal vessel segmentation methods on a new publicly available database," presented at the Medical Imaging 2004: Image Processing, 2004, 5370, pp. 648-657 (2004).

17

A. Hoover and M. Goldbaum, "Locating the optic nerve in a retinal image using the fuzzy convergence of the blood vessels," Medical Imaging, IEEE Transactions on, 22(8), pp. 951-958, (2003).

18

B. Al-Diri, A. Hunter, D. Steel, M. Habib, T. Hudaib, and S. Berry, "A reference data set for retinal vessel profiles," presented at the Engineering in Medicine and Biology Society, 2008. EMBS 2008. 30th Annual International Conference of the IEEE, pp. 2262-2265 (2008).